Quadro Installation Instructions

LOW ENERGY FLUORESCENT LIGHTING
¨ FOR 19.5", USE ONE 32 WATT AND ONE 40 WATT FLUORESCENT CIRCLINE LAMP.

BEFORE YOU START:

Power On-Off.gif (6866 bytes)

IMPORTANT
FIXTURE’S GROUND WIRE MUST BE CONNECTED FOR LAMP TO OPERATE.

CAUTION: IF POWER SUPPLY WIRES OR CORDS ARE LOCATED WITHIN THREE INCHES OF BALLAST, USE WIRE OR CORD SUITABLE FOR AT LEAST 90°C (194°F). TO PREVENT RISK OF FIRE, DO NOT USE FIXTURE ON DIMMING CIRCUITS.

MOUNTING INSTRUCTIONS

  1. Remove fixture from box.

  2. Lay lamp on it’s back (metal surface down).

  3. Remove plastic lens by gently lifting.

  4. Remove bulbs.

  5. Remove mounting hardware from inside of box.

  6. Assemble spring clips to fixture, by positioning clips on the wide end of the “T”-slots with the two downward turned legs of the clips extending through the fixture. Pull the clips away from the fixture center until the clips snap into the “T”-slots. (See Illustration 1)

  7. Attach Lens fastener clips to fixture’s body, through the holes provided near the opposite corners. From the back side of the fixture’s body push the fastening clips through the hole until it snaps into place. Be sure to rotate the clip handles away from the fixture’s edge. (See Illustration 2)

  8. Secure fixture’s mounting screws (only screwing in halfway) to “J-box”.

  9. Using wirenuts connect ground wire (green) from fixture to ground wire from “J-box”. (See Illustration 3)

  10. Using wirenuts connect black wire from fixture to black wire from “J-box”, and repeat the same process with the white wires. (See Illustration 3)

  11. Attach fixture to mounting screws, turn fixture clockwise, and tighten screws. (See Illustration 4)

  12. Plug large circline lamp first. Check the ballast label to determine which lamp plug to use. Place lamp over spring clips, and gently pushing over the third clip. Repeat this procedure for the second (inner) circline bulb. (See Illustrations 5 & 6)

  13. To install acrylic plastic lens, hold lens up to fixture, push handles on lens clips until it is flush against housing.

  14. Restore power at fuse box or circuit breaker box.

Alternate Mntng.gif (5949 bytes)

Line.gif (230 bytes)

Quadro Inst-1.gif (9719 bytes)

Quadro Inst-2-2.gif (11044 bytes)

Quadro Inst-3.gif (7911 bytes)

Line.gif (230 bytes)

Hampton Bay Instructions for 19.5" Quadro

19.5 Quadro Instrn-1.JPG (153724 bytes)

19.5 Quadro Instrn-2.JPG (216403 bytes)

19.5 Quadro Instrn-3.JPG (105451 bytes)

Hampton Bay Warranty.JPG (153313 bytes)
Hamptn Bay Slug.gif (4476 bytes)

WB01337_.gif (904 bytes)
BACK

WB01338_.gif (869 bytes)
HOME

 
Copyright © 2000 Lusa Lighting Inc.